1.Introduction

Driven by the demand to optimize aircraft performance,decrease operation and maintenance costs and reduce noise pollution,the aircraft industry has been pushed towards the concept of the More-Electric Aircraft(MEA).In the MEA,many functions which are conventionally managed by hydraulic,pneumatic and mechanical power,will be replaced with devices driven by electrical power.1,2Such replacement would reduce system weight and volume,increase overall reliability,capability and maintainability,and provide higher durability for aircraft operations.3Aircraft power electronics have also been affected by this trend.The need for power conversion and driving equipment on-board has become significant.Recently,the usage of AC-DC conversion has become a common feature for aircraft power distribution systems.In general,there are two main types of this AC-DC power conversion:the PWM active front-ends and passive multi-phase transformer rectifiers.The former has seen increased application incorporation such as electromagnetic actuators4and electrical starter generator applications.5However,the latter seems to be the main power source for high-power DC load such as aircraft Environment Control Systems(ECS)due to its simple structure and high reliability.The civil aircraft has long been using Transformer rectifier Unit(TRU)to produce 28 VDC from 115 V,400 HzAC sources.However,recently the auto transformer rectifier has received more attention in aerospace industry due to its reduced kVA rating compared with TRUs.6

A number of possible ATRU topologies have been proposed during the last decade.7–13These ATRUs can be categorized into 12-pulse types,18-pulse types,24-pulse types,etc.,according to the number of pulses in the rectified voltage or in the line current during one fundamental cycle.Among these topologies,the 18-pulse ATRU seems to be a preferable option.This is due to the fact that it has higher power quality than the 12-pulse type and less devices than the 24-pulse or other higher pulse type ATRUs.The 18-pulse ATRU is now actually being used on-board B787,the Dream liner,supplying power to the environment control system.14

The 18-pulse ATRUs can be divided into symmetric and asymmetric types depending on the symmetry of voltages on the secondary side of the transformer.For symmetric 18-pulse ATRUs,the voltages on the secondary side of the autotransformer are with the same magnitude(normally the same with the magnitude of voltage on the primary side)and have an equal phase shift of 40°from each other.The load power is equally shared by the three directly-connected diode bridges.For asymmetric 18-pulse ATRUs,however,the voltages on the secondary side are of different magnitudes.The voltage phase shift angle is also not necessarily 40°.

The increased power electronics and motor drives on-board MEA are bringing significant modelling challenges due to its wide variation in time constant.The challenge is to balance the simulation speed against the model accuracy and this is dependent on the modelling task.Four different modelling layers are defined according to the modelling bandwidth,i.e.architectural models,functional models,behavioural models and component models15,16as shown in Fig.1.

The architectural layer computes steady-state power flow and is used for weight,cost and cabling studies.In the functional level,the system components are modelled to handle the main system dynamics up to 150 Hz.The error of models in this level should be less than 5%in respect of the behavioural model accuracy.The behavioural model uses lumped parameter subsystem models and the modelling frequencies can be up to hundreds of kHz.The component models cover high frequencies,electromagnetic field and Electro Magnetic Compatibility(EMC)behaviour,and perhaps thermal and mechanical stressing.The bandwidth of component models can be up to MHz region if required.16

唐飞霄道:“好事赖事,还在大师的一念之间。小生斗胆,请问大师,近日云浮天葬院中,可曾收留了一位中州女子?该女子十六七的年岁,白肤黑发,着绿丝裙,持竹叶刀。”

Fig.1 Multi-level modelling paradigm.16

This paper aims to develop a general functional model of ATRUs which allows future engineers to study ATRUs in a more efficient and effective way.The functional models allow accelerated and accurate simulations and thus enable a wholescale MEA Electrical Power System(EPS)studies in the future.The developed ATRU model is based on the vector concept and in the synchronous dq frame.This method has been widely used in modelling electrical machines.16–18

当前,国内资源化处理危废物料,大多采用鼓风炉冶炼,这种方式存在自动化程度低、工人劳动强度大、环保不容易达标等问题。而无害化处置危废物料通常采用焚烧炉+二燃室工艺。针对鼓风炉工艺和焚烧炉+二燃室工艺处理危废的不足,中国瑞林以侧吹炉炼铜、炼铅技术为基础,进行技术创新,研究开发了侧吹炉富氧侧吹熔池熔炼协同处置技术,在资源化的同时又能无害化处理危废物料,这一技术将加快推进国内危废处理和资源化回收的绿色、环保进程。

The remainder of the paper is organized as follows:Section 2 briefly outlines the operation of ATRUs;Section 3 gives details of the development of the proposed modelling technique;an 18-pule ATRU is used for the effectiveness and efficiency studies in Section 4;Section 5 draws the conclusions of the paper.

2.Operation principles

The design of multiphase transformer rectifiers has been well discussed in Ref.19.The auto-transformer rectifiers normally comprise a phase-shift transformer and a set of three-phase diode bridges as shown in Fig.2.The phase shift transformer is not necessarily an auto-transformer type.However,the auto-transformer is a preferred option due to its low kVA ratings.In this paper,we mainly focus on auto-transformer rectifier units.

As can be observed in Fig.2,the auto-transformer is used to create three sets of three-phase voltages on the secondary side,i.e.(va1,vb1,vc1),(va2,vb2,vc2)and(va3,vb3,vc3).These resultant 9 phases are then fed into three diode bridges supplying power to the dc link.At each instant of time,there are two diodes conducting.These two conducting diodes allow the largest line-to-line voltage to be applied to the DC side.We refer to the ATRU system shown in Fig.2 as a ‘3-9-DC” system.For some ATRUs,especially asymmetric ones,the voltage sources on the primary side of the transformer also feed directly into one diode bridge,i.e.one diode bridge is directly connected to the primary side.In this paper,we consider that the voltage set(va1,vb1,vc1)is the same as that from the primary side,i.e.(va,vb,vc).

取“2.2”项下固定后的肝组织,脱水,石蜡包埋,按4 μm厚度切片。然后进行常规苏木精-伊红(HE)染色,于倒置显微镜下观察,并依据《非酒精性脂肪性肝病诊疗指南》[10],判定肝细胞脂肪变性程度。

Fig.2 General auto-transformer rectifier units.

3.General functional model of 18-pulse ATRUs

A general functional modelling method for the 18-pulse ATRUs will be detailed in this section.Although the development process is similar to our previous work for a symmetric 18-pulse ATRU in Ref.20,this paper extends this modelling technique to more general ATRU topologies and thus covers both symmetric and asymmetric ATRUs.However,the basic concept of model development keeps the same.In summary,development of the functional model will involve the following four steps:

Step 1.Reducing the 3-9-DC system in Fig.2 into a 3-3-DC system as shown in Fig.3,where Reqand Leqare the equivalent resistance and inductance of the autotransformer.This can be achieved using auto-transformer voltage and current relations between primary and the selected channel on the secondary side(marked as vas,vbsand vcsin Fig.3).

Step 2.Transforming the 3-3-DC system into the dq frame.

Step 3.Using the space vector concept to derive the relationship between the chosen channel voltage and current vectors(vsand is)and the recti fied voltage and current vdcand idc.

Step 4.Identifying the equivalent leakage inductance and resistance.

The reduced-order ATRU model is divided into three parts as shown in Fig.3:An ideal transformer,an equivalent RL circuit and an AC/DC converter.The development of functional models for each part will be detailed in the following sections.

3.1.Ideal transformer

For any transformer or auto-transformer,the voltages on the primary side and the secondary side are strongly coupled.Some typical auto-transformers for 18-pulse ATRUs are shown in Fig.4.

Fig.4(a)and(b)show three types of auto-transformer for symmetrical ATRUs and their associated voltage phasor diagrams.It can be seen that the voltage phasors on the primary side(Va,Vb,Vc)and the secondary side(Va1,Vb1,Vc1),(Va2,Vb2,Vc2)and(Va3,Vb3,Vc3)are of the same magnitude.The primary voltages also supply one set of diode bridges directly.The voltage phasors divide the plane equally with 40°phase shift from each other.When these transformers are used for 18-pulse ATRU applications,the primary voltage source,together with the secondary windings,is used to feed the three sets of diode bridges.The auto-transformer shown in Fig.4(c)is an asymmetric auto-transformer where the voltages of the primary and secondary side are of different magnitudes.The phase shift between primary and secondary sides is 37°instead.

The corresponding phase diagram in Fig.4 can be given in Fig.5.

From the phasor diagrams in Fig.5,we can derive that the corresponding three-phase voltages on secondary sides(va2,vb2,vc2)can be given as a function of three-phase voltages(va,vb,vc)on the primary side.One set of the three-phase voltages on the secondary side of the transformer(take va2,vb2and vc2as examples)can be given in a general form irrelevant to the auto-transformer types as

The magnitude of voltage or current vectors in Eq.(10)is equal to its corresponding peak phase value.The relation of vector magnitudes between the primary and secondary sides(the second channel)of the transformer is give as

where k1and k2are the turn ratios between the primary and secondary windings of the transformer.For the con figurations in Fig.5,the turn ratio k1and k2are given as

These parameters can be calculated from the phasor diagram in Fig.5 with designed secondary voltage magnitudes and shift angles.Eq.(1)can be written in matrix form as

where the matrix A is defined as

Assuming that all the power is transferred through the transformer from the chosen channel in order to reduce the system order,we can derive

Fig.3 Equivalent representation of ATRU.

Fig.4 T-Delta and Delta winding con figurations of different types of 18-pulse ATRU.21

Fig.5 Phasor diagram of symmetric T-Delta type,Delta,Polygon winding for symmetric ATRU and asymmetric D-ATRU.

where kpis called the power balance coefficient.This coefficient is to ensure that the power is balanced between primary and secondary sides of the transformer.This coefficient kpis exclusively de pendant on the con figuration of the transformer.The calculation of kpwill be explained in Section 3.2.4.Substituting Eq.(2)into Eq.(4)yields

The transformation from the abc three-phase coordination to the dq frame is considered as

where fabcrepresents variables in the three-phase coordinate;

where θ is the synchronous angle andis the angular speed of the rotating dq frame Transforming Eqs.(2)and(5)by multiplying both sides by Eq.(7)yields

Eqs.(8)and(9)establish the relationship between the voltages and currents of the primary winding and the selected secondary winding of an auto-transformer. The dq transformation,essentially,is to project the voltage and current vectors into a synchronous reference frame.The vector is defined as

初中函数是初中阶段教学的重点难点。初中函数是一个全新的概念,函数的学习与数列、排列组合、方程、不等式等知识点都有着重要的联系,初中数学普遍存在脱离现实生活、教学方法单一的特点,以至于学生学习函数时兴趣不高,课堂氛围不够活跃。教师在函数教学过程中会遇到很多难题,以及函数对逻辑思维能力要求比较高,影响了初中数学函数教学的质量。因此,初中教师应积极丰富初中函数的教学方式,改变传统的教学模式,培养学生的函数解题思维,重视函数的实际应用,摆脱初中数学函数教学的困境,提升初中阶段函数教学的质量。

星雨回想起他们进到万花谷半年来的点点滴滴,进而想起冷雨飞雪里寻找到万花因通道的不易,觉得又伤感又甜蜜,一边将自己的苦恼和盘托出来,希望得到两位伙伴的开解。李离入谷以来,已经变成了内功机关派,古籍整理派,平日向袁安讨论内功既多,得空就去工部,请教僧一行师父,又跟司徒一一先生的几个入门弟子牛星罗、冉间选等来往密切。星雨与万花诸圣学种花栽草,琴棋书画,他虽然也不无兴趣,总觉得太慢、太迂、太文艺,不如内功修习循序渐进,机甲机关切实痛快。

whereis the magnitude of the corresponding vector,and kvis the ratio between the magnitude of voltages on primary and secondary sides of the transformer.The magnitudes of vectors can be calculated in the dq frame as

捕获的过程为:输入的数字中频信号进行混频,得到下变频后的I、Q两路信号,I、Q两路信号分别进入抗混叠滤波器,得到的信号降采样之后存储到容量一定的本地RAM,RAM存满之后开始读取数据至相关支路进行短时相关操作,相关得到的数据存储至相干RAM作复数FFT运算,输出的结果P次相干累加,得到检测量可表示为[14]:

where x can be voltage or current,and^x is the peak value of x.

3.2.AC-DC converter

With the vector concept introduced in Section 3.1 the voltage and current relations for the AC-DC converter parts shown in Fig.3 will be detailed in this section.

9.Burgos R,Uan-Zo-li A,Lacaux F,Wang F,Boroyevich D.Analysis and experimental evaluation of symmetric and asymmetric 18-pulse autotransformer rectifier topologies.Power conversion conference;2007 Apr 2–5;Nagoya.2007.p.1286–93.

For any multi-phase rectifier,the dc-link voltage is always equal to the maximum line-to-line voltage on the AC side at any instant of time.In a phasor diagram,the line-to-line voltage phasors implemented on the DC side of diode bridges are essentially those with the largest distance between two phase voltages as shown in bold dotted lines in Fig.5.For an 18-pulse ATRU,these line-to-line voltage phasors always operate for π/9 period as shown in Fig.6.In addition,each phasor and its opposite phasor(Vcb1and Vb1cfor example)are with the same terminals but connected to dc-link capacitor in opposite.

It can also be noticed that for symmetric ATRUs,each diode carries 2π/9 period of idc.For example,during the period with phasors from Vc2b1to Vcb1then Vca2,the lower diode at phase b1 conducts for π/9 when Vc2b1is active and another π/9 when Vcb1is active as shown in Fig.6(a).

For the asymmetric,however,the terminals(a1,b1,c1)&(a2,b2,c2)on the secondary side conduct for only π/9 as shown in Fig.6(b).

For example,from Vacto Vac2and then Vab1,the terminal c2 only conducts for π/9 period.

Fig.6 Line-to-line voltage phasor reflected on DC-link side of ATRU.

Fig.7 Relations between line-to-line voltages and DC-link voltage.

Considering that the line-to-line voltage phasors are of the same magnitude and each of them functions for π/9 period,the relation between the dc-link voltage and line-to-line voltages is shown in Fig.7.

With Fig.7,we can derive that the dc-link voltage vdcis the average value of a line-to-line voltage around its peak for a period[-π/18,π/18]and can be given as

The generic functional model has been successfully implemented to a D-type symmetric 18-pulse ATRU in our previous publication.20In this section,we will demonstrate the effectiveness of the technique in modelling a D-type asymmetric ATRU.This asymmetric ATRU,shown in Fig.4,will be tested and validated by comparison to a corresponding behavioural model under both balanced and unbalanced conditions.The original behavioural model of the ATRU was developed in SABER provided by our industrial partner and has been validated before release.The behavioural model(ABC model)considers the leakage inductance of the transformer as well as the switching behaviour of the diodes in the converter.The simulation scheme is shown in Fig.10.Simulations have been performed on an Intel i7 CPU@3.20 GHz,24.0 GB of RAM using Dymola/Modelica v.7.4 software.The behavioural model is redeveloped in the Dymola from the original SABER model to enable the computation time studies comparing the behavioural model and the functional model.The RadauIIa algorithm has been chosen in the solver and the tolerance has been set at 1×10-4.As a quantitative evaluation of the computational efficiency of these modelling techniques,the computation time has been compared.Meanwhile,the evaluation of the accuracy is performed by comparing the plots of the system quantities.

8.Paice DA.Nine-phase step-up/step-down autotransformer.United States Patent 7274280;2007 September 25.

The authors gratefully acknowledge the EU FP7 funding via the Clean Sky JTI–Systems for Geen Operations ITD.

As mentioned before,the conduction period of each phase at the secondary side of the ATRUs is dependent on the topology of the transformers.If we only consider the fundamentals of the currents at the AC side of the diode bridges,the relationship between i2and idccan be written as

The angle φ is half of the conduction period of diodes connected to the selected channel.For asymmetric ones,φ is π/9.For asymmetric ones shown in Fig.4,φ is equal to π/18.If we neglect the internal inductance,the snubber resistance,and the capacitance of the diodes and assume there is no energy storage within a diode rectifier,the fundamental components of voltage and current on the AC side are in phase.Thus the phase angle of the AC current vector can be given from the voltage vector as

Hence,the currents on the d and q axes are

3.2.3.Commutation loss

Analysis of commutation loss for an 18-pulse rectifier can begin from the study of a 6-pulse diode rectifier.Considering that the commutation occurs every π/9,the voltage drop thus can be expressed as

Table 1 Relations between DC-link voltage vdcand voltage vectors of auto-transformers.

*This row considers the relation betweenandas illustrated in Eq.(11).

Combining dc-link voltage in Table 2and Eq.(19),the DC link voltage can be written as

3.2.4.Calculation of kp

The power balance coefficient kpis derived using the principle of power balance between the AC and DC sides of the ATRU.This has been detailed discussed in Ref.20and will be briefly introduced in this section.

第一,外校考入本校研究生在本科阶段只学习了工程热力学和传热学等基本课程,缺乏对燃气轮机专业知识的学习,导致入学之后学习我校研究生课程存在一定的困难,在课程结束之后也很难进入研究课题。第二,研究生入学后,以导师研究方向选择相应的课程和开展相关课题研究,学生毕业之后只熟悉自己的研究领域,不了解燃气轮机其他研究方向的内容。燃气轮机的设计是一个团队协作的工作,因此很难有效开展研究。第三,缺乏系统深入的了解,燃气轮机整体性能知识储备不足,不能满足研究生阶段及其参加工作后对于燃气轮机系统分析的需要。

The power on the DC side can be calculated as

比如在《可爱的动物》主题中我结合小班孩子对动物动作特点的认识开展了“小兔拔萝卜”、“猫捉老鼠”、“小鸟找家”、“小狗练本领”等晨间户外游戏,投放的材料大多是一些布制的、颜色鲜艳、形态逼真的材料,既符合小班孩子的特点调动起孩子积极参与的兴趣,又让孩子们在愉快的游戏中练习了动作。

Assuming that there is no provision for energy storage and power losses in the diode bridge,the fundamental component of current at the input must be in phase with the input voltage(as the output current is in phase with the output voltage).19The power at the AC side can be expressed as

标准是社会发展和科技进步的必然产物。远古时代,原始的自然人基于标准化活动形成统一的语言、文字、工具和建筑规格,这些标准化结果就是人类文明进步的成果。进入以社会化大生产和大规模机器生产为基础的近代标准化阶段,标准零部件、标准时间、作业规范及连续生产流水线就是基于标准化活动获得的科技进步的成果。

Using power balance Pdc=Pacand combining Eqs.(21)and(22),we can derive

3.3.Equivalent RL circuit

The parameters Leqand Reqare given as

Table 2 Turn ratios for different auto-transformers.

Auto-transformer types Values of k1and k2T type in Fig.4(a) k1=0.51,k2=0.27 D type in Fig.4(b) k1=0.51,k2=0.27 D type in Fig.4(c) k1=0.45,k2=0.24

Fig.8 18-pulse asymmetric ATRU model in dq frame.

where Lpand Lsare the primary and secondary leakage inductances respectively,Rpand Rsare the primary and secondary winding resistances respectively,and N is the turn ratio between the primary and secondary windings.

Summarizing this section,the developed DQ model of the overall asymmetrical ATRU can be presented by Fig.8.As can be seen,the model includes three parts,i.e.the transformer,RL circuits and the converter.The auto-transformer and converter are represented as controlled current and voltage sources.The developed DQ model can be interfaced with other models developed in the dq frame as in Ref.16,22,where ideal three-phase sources,synchronous machines,transmission lines,etc.are introduced.A three-phase voltage source will become two DC sources in the dq-frame model,as shown in Fig.8.The developed DQ model can connect with models developed in the three-phase coordinate frame,by using a three-phase to dq frame interface.The developed model can be used for both balanced and unbalanced conditions as discussed in Ref.20.The procedure of developing functional models of asymmetric ATRUs can be summarised by the flowchart in Fig.9.

4.Simulation results of asymmetric example

whereis the magnitude of line-to-line voltages in Fig.6 and can be calculated from phase peak voltage value.With Eq.(14),we have the following table.

Fig.9 Flowchart for development of ATRU DQ models.

4.1.Line-to-ground fault

In this section,the developed DQ model is simulated and tested under line-to-ground fault conditions.The simulation scheme is shown in Fig.10.The ATRU is supplied by an ideal three-phase voltage source with phase voltage Vs=230VRMS@400 Hz.The transmission line is modelled as an RL circuit with RT=0.1 Ω and LT=1 μH.The DC-link capacitance C=260 mF and the load resistance is set at 10 Ω.A line-to-ground fault is applied between phase A and the ground at the front end of the ATRU and the fault resistance Rfaultis set at 100 μΩ.Simulation results from the ABC model and the DQ model are compared in Fig.11 and Fig.12.From Fig.11,it can be seen that under balanced conditions,the DC-link voltage vdcin the ABC model includes high switching harmonics,while vdcfrom the DQ model is with a constant value.Under line-to-ground fault conditions,a second harmonic(800 Hz)appears in the DC-link voltage of both the ABC and DQ models.This is mainly due to the fact that with an unbalanced power supply,the multi-pulse rectifier is reduced to a single-phase diode rectifier.In the DQ model,the second harmonic appears in both d and q axes.The results from the two models are very well matched under both balanced and unbalanced conditions.The AC currents flowing into the ATRU are shown in Fig.11.The currents from the ABC model and DQ model match very well under both balanced and line-to-ground fault conditions.After the line-to-ground fault occurs at 0.1 s,since phase A is short-circuit to the ground,there is only a small leakage current,ia, flowing through phase A.

4.2.Line-to-line fault

The developed model was also tested under line-to-line fault conditions.The system scheme is shown in Fig.10 with a line-to-line fault between phase A and phase B at t=0.05 s.The parameters keep the same as those used in Section 4.1.

Fig.11 DC-link voltage comparison between ABC model and DQ model with a line-to-ground fault occurring at t=0.1 s.

Fig.12 Comparison of AC side currents within ABC model and DQ model with a line-to-ground fault occurring at t=0.1 s.

The DC-link voltage at the output of the ATRU,and currents flowing into the ATRU,are shown in Figs.13 and 14 respectively.As can be seen from these two figures,the results from the DQ model and the ABC model match very well under both balanced and line-to-line fault conditions.It is important to note that both models match very well after the fault occurs;phase A and phase B equally share the currents under line-toline fault conditions and the sum of these two currents is equal to the current flowing in phase C ic.

Fig.10 Simulation scheme of ATRU under line fault conditions.

Fig.13 DC-link voltage comparison between ABC model and DQ model with a line-to-line fault occurring at t=0.05 s.

Fig.14 Comparison of AC side currents within ABC model and DQ model with a line-to-line fault occurring at t=0.05 s.

Table 3 CPU time comparison between ABC and DQ models.

Scenario ABC DQ Acceleration Before fault(0–0.05 s) 72.08 0.12 600 Total time(0–0.1 s) 86.52 5.081 17

Table 3 shows the computation time required by the two models under both balanced and unbalanced conditions.It can be seen that before the fault occurs,the DQ model is 600 times faster than the ABC model.This is because under balanced conditions,all the variables in the DQ model are DC-like.This allows the computer to use larger simulation steps.However,after the fault occurs,the simulation speed of DQ model decreases sharply.This is due to the second harmonics included in the DQ model under unbalanced conditions.Table 3 and Fig.15 give a comparison of the CPU time required by the two models.Interestingly,Fig.15 also shows that the simulation speed of the ABC model under line-to-line fault conditions is faster than that under balanced conditions.This is due to the fact that with a line-to-line fault,or under unbalanced conditions,the number of conducting diodes in one period is reduced,i.e.less switching behaviour in one period.

Fig.15 CPU time comparison between ABC and DQ models with a step load change at t=0.02 s and a line-to-line fault implemented at t=0.05 s.

5.Conclusions

In this paper,an averaging functional model framework based on the vector concept was introduced to study both symmetric and asymmetric ATRUs.The development of the functional model consisted of three steps:reducing the order of the system,transforming the reduced-order system into the DQ frame and de fining the equivalent leakage inductance and resistance.The generic DQ model developed in this paper provides an accurate and computationally efficient method of modelling both symmetric and asymmetric ATRUs.In addition,the developed model can be conveniently connected to other functional DQ models developed from previous work.The interface between the DQ model and the ABC model can also be conveniently developed using a DQ/ABC transformation.Under balanced conditions,the DQ model is 600 times faster than ABC models.Under unbalanced conditions,the simulation speed of the DQ model decreases sharply.This is due to the double frequency in both d and q axes.The dynamic phasor technique is a potential method to handle an unbalanced system effectively.The dynamic phasor model for the 18-pulse ATRU is under development and will be published in future.

Acknowledgment

3.2.2.Current

References

这七绝逍遥阵由侠客岛北斗七星阵变动而来,方乾在侠客岛穷海之边,夜参北斗,由星辰运转之中,悟出内力变化,得七七四十九变,可由七人、十四人、二十一人,一百四十七人,直至七百人形成大中小北斗七星阵,以门客家丁席卷来攻侠客岛的敌人,实是侠客岛第一防守奇阵。

1.Quigley REJ.More electric aircraft.Applied power electronics conference and exposition;1993.p.906–11.

2.Sarlioglu B,Morris CT.More electric aircraft:review,challenges,and opportunities for commercial transport aircraft.IEEE Trans Transport Electrific 2015;1(1):54–64.

3.Uan-Zo-li A,Burgos R,Wang FD,Boroyevich F,Tardy A.Comparison of prospective topologies for aircraft autotransformer-rectifier units.Conference of the IEEE industrial electronics society;2003 Nov 2–6;Roanoke.Piscataway:IEEE Press;2003.p.1122–7.

4.Wheeler P,Trentin A,Bozhko S,Clare J.Regeneration of energy onto an aircraft electrical power system from an electro-mechanical actuator.Electrical systems for aircraft,railway and ship propulsion;2012 Octo 16-18;Bologna.2012.p.1–6.

罗爹爹说:”话是这样说,但就怕大家受不住,已经都听了一个星期了。我这两天腿子走不得,没有去打拳,我也听得心里慌慌神。你晓得,这个音乐蛮不吉利。”

5.Bozhko S,Yeoh SS,Gao F,Hill C.Aircraft starter-generator system based on permanent-magnet machine fed by active frontend rectifier.40th annual conference of the IEEE industrial electronics society;2014 Oct 29–Novermber 1;Dallas.Piscataway:IEEE Press;2014.p.2958–64.

6.Choi S,Enjeti PN,Pitel IJ.Polyphase transformer arrangements with reduced kVA capacities for harmonic current reduction in rectifier-type utility interface.IEEE Trans Power Electron 1996;11(1):680–90.

本文通过对样品中氯化物种类进行分析,选用氧弹燃烧法、艾士卡法[13]、水萃取法和 XRF法[14]分别对样品中的Cl含量进行量化。通过对上述不同方法测出的结果进行对比分析,提出一种较为适合且更能准确地量化城市固体废弃物中 Cl含量的方法,以期弥补当前的 Cl测定方法的不足,提高 Cl含量测定的准确性。

7.Kamath GR,Benson D,Wood R.A novel autotransformer based 18-pulse rectifier circuit.Applied power electronics conference and exposition;2002 Mar 10–14;Dallas.2002.p.795–801.

In Table 1,is the maximum value of the phase voltage vaand is equal to the magnitude of v,denoted as,andis the maximum value of the phase voltage va2and is equal to the magnitude of va2.

3.2.1.Voltage

10.Wu X,Cai P,Zhang X.Design and analysis of an autotransformer based 24-pulse rectifier.International conference on electrical and control Engineering;2010.p.3529–3532.

1.2.1.3保持持续质量改进护士长经常不定期检查,找出目前存在的问题,并定期组织讨论,改进问题和总结经验,形成一套正确的规章流程,制定评价制度,不断调整使6S管理持续而有效的运行起来。

11.Singh B,Bhuvaneswari G,Garg V.A novel polygon based 18-pulse AC/DC converter for vector controlled induction motor drives.IEEE Trans Power Electron 2007;22(2):488–97.

12.Kalpana VS,Singh B.Improvement in harmonic reduction of zigzag autoconnected transformer based 12-pulse diode bridge rectifier by current injection at DC side.IEEE Trans Indust Appl 2017;53(6):5634–41.

13.Wang T,Fang F,Jiang X,Wang K,Yang L.Performance and design analysis on round-shaped transformers applied in rectifier systems.IEEE Trans Indust Electron 2017;64(2):948–55.

14.Nelson T.787 systems and performance.Chicago:The Boeing Company;2005.

15.Mohan N,Robbins WP,Undel and TM,Nilssen R,Mo O.Simulation of power electronic and motion control systems-an overview.Proc IEEE 1994;82(8):1287–302.

16.Bozhko S,Wu T,Hill C,Asher G.Accelerated simulation of complex aircraft electrical power system under normal and faulty operational scenarios.36th annual conference on IEEE industrial electronics society;2010 Nov 7–10;Glendale.Piscataway:IEEE Press;2010.p.333–8.

17.Krause PC,Asipo TA.Analysis and simplified representations of rectifier–inverter reluctance-synchronous motor drives.IEEE Trans Power Appar Syst 1969;PAS-88(6):962–70.

18.Ong CM.Dynamic simulation of electric machinery using Matlab/Simulink.Dover:Prentic-Hall;1997.

19.Paice DA.Power electronic converter harmonics:multipulse methods for clean power.Hoboken:Wiley-IEEE Press;1996.

20.Yang T,Bozhko S,Asher G.Functional modeling of symmetrical multipulse autotransformer rectifier units for aerospace applications.IEEE Trans Power Electron 2015;30(9):4704–25.

21.Uan-Zo-li A,Burgos R,Lacaux F,Roshan A,Wang F,Boroyevich D.Analysis of new step-up and step-down direct symmetric 18-pulse topologies for aircraft autotransformer-rectifier units.IEEE 36th power electronics specialists conference;2005 June 16;Recife.Piscataway:IEEE Press;2005.p.1142–8.

22.Wu T,Bozhko S,Asher G,Thomas D.Accelerated functional modeling of aircraft electrical power systems including fault scenarios.35th annual conference of IEEE industrial electronics;2009 Nov 3–5;Porto.Piscataway:IEEE Press;2009.p.2537–44.

Tao YANG,Serhiy BOZHKOa,Patrick WHEELERa,Shaoping WANGb,Shuai WUb